TECHNOLOGIES, INC.           The Art and Science... of Wastewater Treatment

A "Green" company
 since 1990

                   

Products

Batch and Continuous Flow Chemical Reaction Systems

pH adjustment, neutralization, precipitation and specialty chemical reaction systems

Clarifiers

Inclined Plate (IPC) Clarifiers

Control Panels

World class PLC and relay logic based panels

DAF (dissolved air flotation) Flotation Systems

Traditional and lamella plate dissolved air flotation (DAF) systems

Media Filters

Sand (deep bed and high rate), multi-media and specialty filters

Media Packs

Media Packs for oil / water (immiscible liquids), DAF, sedimentation and custom separation systems

Oil Water Separators

API, enhanced gravity and pressurized separators suitable for any application

Packaged Systems

Pre-packaged turnkey systems for hundreds of applications

Pump Packages

Centrifugal, positive displacement and progressive cavity pump packages

HFT....

About Us

• Company Profile

Customer List

Contact Us

Phone, E-mail, Fax, Etc...

Below is a link to an API oil water separator sizing spreadsheet developed by Hydro-Flo Technologies.

By inputting the major design criteria, you can solve for the separation chambers width to length to depth ratios.

The spreadsheet operates on Microsoft Excel 2003 or later.

API sizing calculations

Below is a sample shot of the spreadsheet.

Hydro-Flo Technologies, Inc.
The Art and Science... of Wastewater Treatment 
         
  Company  
  Location  
         
API Separator Calculations          
         
USER INPUT IN YELLOW        
Design Flow rate (in gpm) 250        
Temperature (in deg F) 60        
Specific Gravity of the Oil (in g/cm3) 0.850        
Oil Droplet size (in microns) 150        
Density of the Water (in g/cm3) 0.99890        
Viscosity (in Poise) 0.01129        
         
For more detailed information go to www.HydroFloTech.com  
         
RESULTS    
  Width of separator in feet 6.500    
  Depth of separator in feet 2.500    
  Length of separator in feet 32.500    
         
Oil Droplet (in cm) 0.015        
         
Call 630-762-0380 to talk to a Hydro-Flo application engineer  
         
  Minimum Allowable Result Design Maximum Allowable Result    
terminal velocity (in cm/s) 0.162 0.162 0.162    
terminal velocity (in ft/min) 0.318 0.318 0.318    
Minimum cross sectional area needed (in ft) 11.139 11.139 11.139    
Cross Sectional Area (in square feet) 11.139 16.250 160.000    
maximum horizontal velocity (15*vt, but must be <=3) 3.000 3.000 3.000    
horizontal velocity (in ft/min) 3.000 2.057 0.209    
vh/vt 9.423 6.459 0.656    
short-circuiting factor 1.491 1.395 1.194    
Length of unit (must be at least 5X of width) (in ft) 5.000 32.500 100.000    
length/width 5.000 5.000 5.000    
minimum horizontal area 156.527 146.444 125.341    
Width of channel (in feet) (must be 6 to 20) 1.000 6.500 20.000    
Rectangular Callout: Adjust the depth and width until you get a horizontal velocity <=3.  Ideal horizontal velocity should be in the <=2 range at average flow.  Make sure that you maintain a depth/width ratio of .3 to .5
Depth (in feet)
0.300 2.500 10.000    
Depth/Width Ratio (must be .3 to .5) 0.300 0.385 0.500    
         
         
         
         
         
         
         
         

Why Choose
Hydro-Flo Technologies

 

Employment
Opportunities

 

Engineering Tools

Typical Applications

Follow this link to our library of application P&ID's and process descriptions

Application Questionnaire

Follow this link to our equipment application questionnaire

Clarifier Sizing information

Inclined Plate Clarifier Design Parameters
Detailed information on the design and sizing of inclined plate clarifiers and clarification systems

Dissolved Air Flotation System Design & Sizing information

Dissolved Air Flotation Design Parameters
Detailed information on the design and sizing of dissolved air flotation separators and separation systems

Oil Water Separator Design & Sizing information

Oil Water Separator Design Parameters
Detailed information on the design and sizing of oil water separators and separation systems

Misc Info, Data, Spreadsheets & Calculations

EPA Non-Polar Oil Test Methods

Fluid Mechanics

Reynolds Number Calculations

Water Hammer Calculations

HFT Quality Control

HFT Quality Assurance Plan

Steel Fabrications

Leak Test Certification

Interior Coatings

Exterior Coatings

Control Panels

Chemical / Material Compatibility Data

Chemical Pump Dosing Rates

Chemical Compatibility Chart

Properties of Plastic

Coating / Materials Data

Surface Prep Definitions

Standard Internal Coating

Standard External Base Coating

Standard External Top Coating

FRP Resin Cut Sheets

Gel Coat Cut Sheet

Wastewater Treatment Equipment